Home › Reverse Osmosis › RO Systems › US Water Systems Maverick Lite Commercial RO System – 200 to 750 GPD
RO Systems

US Water Systems Maverick Lite Commercial RO System – 200 to 750 GPD

Original price was: $799.00.Current price is: $159.80.
🚚 Free Shipping over $39
✓ Premium Quality
🔒 Secure Payments
↻ Money Back Guarantee
SKU: 220-MAV : 220-MAV-500
CATEGORY: RO Systems
Description

200 GPD to 750 GPD LITE COMMERCIAL REVERSE OSMOSIS SYSTEMS

Like all Reverse Osmosis Systems manufactured in the USA by US Water Systems, we source as many components as possible from American Manufacturers. Our frames, filter housings, filters, membranes, tanks and the like are all sourced from American Companies. Our systems are also assembled in the USA by American Craftsmen (and Craftswomen).

Choose the System That is Right for You

Four Models

200 GPD Line Pressure

350 GPD Line Pressure

500 GPD Booster Pump

750 GPD Booster Pump

Six Tanks

14 Gallon Metal

(Non-USA)

20 Gallon Metal

(Non-USA)

20 Gallon Composite
(Made in USA)

40 Gallon Composite
(Made in USA)

80 Gallon Composite
(Made in USA)

120 Gallon Composite
(Made in USA)

FEATURES AND BENEFITS

  • Lightweight – Can be mounted on the wall or floor
  • Powder-Coated Frame – Will not rust
  • Pre-Plumbed & Assembled – Ready to install
  • 5-Year Warranty – Built to Last
  • 5-Stages-Maximum Filtration
  • Maximum Chemical Removal
  • Removes both Chlorine & Chloramine

100% BPA Free – Here’s Why

BPA (bisphenol A) is a chemical that is added to many commercial products, including food containers and hygiene products. It was first discovered in the 1890s, but chemists in the 1950s realized that it could be mixed with other compounds to produce strong and resilient plastics.

BPA is said to mimic the structure and function of the hormone estrogen. Due to its estrogen-like shape, BPA can bind to estrogen receptors and influence bodily processes, such as growth, cell repair, fetal development, energy levels, and reproduction. In addition, BPA may also interact with other hormone receptors, such as those for your thyroid, thus altering their function.

Your body is sensitive to changes in hormone levels, which is the reason why BPA’s ability to mimic estrogen is believed to affect your health.

TYPICAL CONTAMINANT
REDUCTION — 93% TO 99.99%

Contaminant Reduction
Algae 99.90%
Aluminum 98.00%
Amoebic Cysts 99.00%
Arsenic 95.00%
Asbestos 99.00%
Atrazine 95.00%
Bacteria 95.00%
Barium 97.00%
Calcium 99.50%
Chloride 95.00%
Chlorine 99.90%
Chromate 94.50%
Copper 99.00%
Cryptosporidium Cysts 97.00%
Cyanide 97.00%
Fluoride 98.00%
Giardia Lamblia Cysts 99.00%
Lead 97.00%
Manganese 98.00%
Magnesium 97.00%
Contaminant Reduction
Mercury 98.00%
Mold 99.90%
Nickel 95.00%
Nitrate 89.00%
Phosphate 95.00%
Potassium 95.00%
Protozoa 99.00%
Radioactivity 95.00%
Sediment 99.00%
Selenium 95.00%
Silicate 89.00%
Silver 97.00%
Sodium 94.00%
Strontium 97.00%
Sulfate 95.00%
Thiosulfate 99.00%
Trihalomethane 98.00%
Volatile Organics 95.00%
Zinc 97.00%
Z, 4-D 95.00%

SPECIFICATION

Design 200 GPD 350 GPD
Configuration Single Pass Single Pass
Feed Water Source TDS < 1000 TDS < 1000
Standard Recovery Rate 25% 53%
Rejection and Flow Rates
Nominal Salt Rejection % 97.5 97.5
Permeate Flow* gpm (lpm) 0.13 0.24
Concentrate Flow gpm (lpm) 0.39 0.21
Connections
Feed inch 3/8″ Tube 3/8″ Tube
Permeate inch 3/8″ Tube 3/8″ Tube
Concentrate inch 1/4″ Tube 1/4″ Tube
Membranes
Membranes(s) Per Vessel 1 1
Membrane Quantity 2 1
Membrane Size 1.8 x 12 3 x 12
Vessels
Vessel Array 1:1 1
Vessel Quantity 2 1
Systems Dimensions ***
L x W x H inch 17 ⅜” x 6 ½” x 34 ⅝” 17 ⅜” x 6 ½ x 33 13 ⁄16“
Weight lb. 33 35
Operating Limits
Maximum Feed Temperature °F (°C) 85 (29.00) 85 (29.00)
Minimum Feed Temperature °F (°C) 40 (4.44) 40 (4.44)
Maximum Ambient Temperature °F (°C) 120 (48.89) 120 (48.89)
Minimum Ambient Temperature °F (°C) 40 (4.44) 40 (4.44)
Maximum Feed Pressure psi 85 85
Minimum Feed Pressure psi 45 45
Maximum Operating Pressure psi 120 120
Maximum SDI Rating SDI < 3 < 3
Maximum Free Chlorine ppm 0 0
Maximum TDS ppm 1000 1000
Maximum Hardness gpg 10 10
Maximum pH (Continuous) 11 11
Minimum pH (Continuous) 3 3
Maximum Turbidity NYU 1 1
Design 500 GPD 750 GPD
Configuration Single Pass Single Pass
Feed Water Source TDS < 1000 TDS < 1000
Standard Recovery Rate 50% 50%
Rejection and Flow Rates
Nominal Salt Rejection % 97.5 97.5
Permeate Flow* gpm (lpm) 0.35 0.52
Concentrate Flow gpm (lpm) 0.35 0.52
Connections
Feed inch 3/8″ Tube 3/8″ Tube
Permeate inch 3/8″ Tube 3/8″ Tube
Concentrate inch 1/4″ Tube 1/4″ Tube
Membranes
Membranes(s) Per Vessel 1 1
Membrane Quantity 2 2
Membrane Size 3 x 12 3 x 12
Vessels
Vessel Array 1 1:1
Vessel Quantity 1 2
Systems Dimensions ***
L x W x H inch 20 15⁄16” x 6½” x 3313⁄16“ 20 13⁄16” x 6½” x 37⅞”
Weight lb. 40 43
Operating Limits
Maximum Feed Temperature °F (°C) 85 (29.00) 85 (29.00)
Minimum Feed Temperature °F (°C) 40 (4.44) 40 (4.44)
Maximum Ambient Temperature °F (°C) 120 (48.89) 120 (48.89)
Minimum Ambient Temperature °F (°C) 40 (4.44) 40 (4.44)
Maximum Feed Pressure psi 85 85
Minimum Feed Pressure psi 45 45
Maximum Operating Pressure psi 120 120
Maximum SDI Rating SDI < 3 < 3
Maximum Free Chlorine ppm 0 0
Maximum TDS ppm 1000 1000
Maximum Hardness gpg 10 10
Maximum pH (Continuous) 11 11
Minimum pH (Continuous) 3 3
Maximum Turbidity NYU 1 1

WHAT’S INCLUDED

MAVERICK 200 GPD

MAVERICK 350 GPD

MAVERICK 500 GPD

MAVERICK 750 GPD

Product Information

Scroll to Top